ST VLUX-015S - VERMICULUX-S®
3-Sided beam protection up to 609mm deep and 380mm wide. Board fixed to angle.
A third party certified solution which maintains the loadbearing capacity of structural steel for up to 240 minutes. This system can provide protection to limiting steel temperatures between 350°C to 750°C. Can be installed before the building is weathertight.