Name
|
Fire resistance
|
Total Thickness
|
Rw
|
|
---|---|---|---|---|---|
|
|
||||
|
FRL 60/60/60 Ceiling under steel frame timber floor with PROMATECT®-100 1 x 20mm - against fire from below
FRL 60/60/60 Ceiling under steel frame timber floor with PROMATECT®-100 1 x 20mm - against fire from below
|
60 min | 253 mm | 36 dB | |
|
![]() FRL 60/60/60 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and a 20mm PROMATECT®-100 ceiling - against fire from above and below
FRL 60/60/60 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and a 20mm PROMATECT®-100 ceiling - against fire from above and below
|
60 min | 256 mm | N/A | |
|
Weather Defence™ Bushfire roof system
Weather Defence™ Bushfire roof system
|
120 min | N/A | N/A | |
|
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 1 x 20mm on both sides - against fire from above and below
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 1 x 20mm on both sides - against fire from above and below
|
240 min | 105 mm | 41 dB | |
|
FRL -/240/240 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm on both sides - against fire from above and below
FRL -/240/240 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm on both sides - against fire from above and below
|
120 min | 156 mm | 39 dB | |
|
![]() FRL 90/90/90 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and a 20mm PROMATECT®-100 ceiling - against fire from above and below
FRL 90/90/90 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and a 20mm PROMATECT®-100 ceiling - against fire from above and below
|
90 min | 256 mm | N/A | |
|
FRL 120/120/120 Ceiling under steel frame timber floor with PROMATECT®-100 2 x 20mm - against fire from below
FRL 120/120/120 Ceiling under steel frame timber floor with PROMATECT®-100 2 x 20mm - against fire from below
|
120 min | 278 mm | 39 dB | |
|
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm and cover strip - against fire from above
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm and cover strip - against fire from above
|
120 min | 150 mm | 36 dB | |
|
FRL 120/120/120 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and 2 x 15mm PROMATECT®-100 ceiling - against fire from above and below
FRL 120/120/120 Steel frame composite floor with Promat SYSTEMFLOOR™ FR as floor panel and 2 x 15mm PROMATECT®-100 ceiling - against fire from above and below
|
120 min | 266 mm | N/A | |
|
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm and cover strip - against fire from below
FRL -/120/120 Self-supporting membrane ceiling with PROMATECT®-100 2 x 20mm and cover strip - against fire from below
|
120 min | 150 mm | 36 dB |


Horizontal Compartmentation
Promat offers a complete range of fire compartmentation solutions based on multiple tests according to AS standards. In this section you will find Promat's solutions for the horizontal compartmentation of load-bearing floor systems, brushfire roof and membrane ceilings.