FRL 120/-/- Steel column protection cladded with PROMATECT®-XS

  • Assembling a double layer of PROMATECT®-XS board. Either 2x15mm or 15+20mm thick. Encases the steel member and fix the boards with staples.

Further Information

Fire resistance: 120 min
Product: PROMATECT®-XS
Advantages:
  • Dimensionally stable
  • Quick, easy to cut and install saving time and reducing installed cost
  • Frameless system minimises space
  • No requirement for adhesive or joint fillers
  • Smooth, impact resistant surface
  • Water, weather and mould resistant
  • Can be installed before the building is weathertight (up to 6 months semi-exposed)
  • Certified to AS 4100 and AS 1530.4:2014
  • High levels of fire protection to structural steelwork
Application:
  • Commercial, industrial, institutional, residential and high rise constructions, or in the restoration of existing buildings
Exposure to fire: External
Fire Resistance Level: FRL 120/-/-
Fire resistance: 120 min

Downloads